UNI-BANK RP

UNI-BANK RP

Back-wall anti-contamination bank

Description

PLP version (Plenum and Panel) for filter replacement pharma side.

Back-wall anti-contamination bank with 1 or 2 stages sealed in class L1 according to EN 1886:2008 (test pressure @ 5000 Pa) with sealing plenum resting on the wall for replacing filters on the Pharma side, set up for a rigid pocket filter (T ) and/or an absolute filter (H) tightened by cam shafts and safety lock to prevent the door from closing if the filter element is not correctly positioned. Complete with lower 90° connection with support legs and adjustable feet. Rounded edges flat frame chassis with removable blind panel for plenum sealing closure. Chassis with flat frame with rounded edges and intake perforated grille with air passage 50% (open area) that can be removed by means of hidden screws. Supplied with control sockets, barrier bags and fixing elastics bands

 

PLP ▢ DHS version (Plenum and Panel) for pharma-side filter replacement with additional modules for absolute filter integrity testing.

1- or 2-stage rear-wall canister contamination control bench, class L1 airtight according to EN 1886:2008 (test pressure @ 5000 Pa) with wall-mounted plenum for pharma-side filter replacement, designed for a deep-pleat filter (A) and/or an absolute filter (H).

Built as a PLP version with an integrated system comprising:

  • MD Distributor Module, consisting of a fixed multi-point probe with automatic connection for test aerosol injection, an internal distribution section, and a fixed multi-point probe with automatic connection for 100% detection of the test aerosol upstream of the absolute filter.
  • MS Scanning Module, consisting of a transverse multi-point probe with a sealed sliding rod for scanning detection of the test aerosol downstream of the absolute filter, complete with automatic connection and sealing device

R (Reversed) version for filter replacement on the technical compartment side.

1- or 2-stage rear-wall anti-contamination cabinet, class L1 airtight according to EN 1886:2008 (test pressure @ 5000 Pa) with reversed access for filter replacement on the technical compartment side, designed for a rigid bag filter (T) and/or an absolute filter (H).

Construction as PLP version but without sealing plenum and removable blank panel.

 

Available versions

  • UC-RP-R ▢ Single-stage filter replacement, technical compartment
  • UC-RP-R ▢ DHS single stage filter replacement technical compartment with integrated MD distributor module and MS scan module for filter integrity testing
  • UC-RP-PLP ▢ Single-stage filter replacement, pharmaceutical side
  • UC-RP-PLP ▢ DHS  Single-stage filter replacement, pharmaceutical side with integrated MD distributor module and MS scanning module for filter integrity testing
  • UB-RP-R ▢ Double-stage filter replacement, technical compartment
  • UB-RP-R ▢ DHS double stage filter replacement technical compartment with integrated MD distributor module and MS scanning module for filter integrity testing
  • UB-RP-PLP ▢ Double-stage filter replacement, pharmaceutical side
  • UB-RP-PLP ▢ DHS Double-stage filter replacement, pharmaceutical side with integrated MD distributor module and MS scanning module for filter integrity testing

Special executions

  • UB RP Spec 013 - stainless steel execution Aisi 304
  • UB RP Atex - Atex execution II 2 G/D